$985.00

HIGH PERFORMANCE, LONG LASTING, SAFE BATTERIES FOR TOUGH, CRITICAL APPLICATIONS

NEC Energy Solutions ALM line of lithium Nanophosphate® battery modules offer exceptional performance and long operating life. Compared to typical lead-acid batteries, the ALM 12V35 line delivers:

  • > 50X longer cycle life
  • 5X longer calendar / float life
  • 10X faster recharge time
  • 60% more usable capacity vs. nameplate at high current
  • 50% lower weight

Integrated protection for short circuits and over-voltage, temperature, charge and discharge add to the inherent Nanophosphate® cell safety. Consistent energy capacity, even under high discharge and deep cycling, allows system right-sizing, while arrays up to 48V and 350Ah extend application flexibility.

Name Range Discount
ALM12V35i HP 10 - 24 $35.00
ALM12V35i HP 25 - 99 $95.00
ALM12V35i HP 100 - 499 $145.00
ALM12V35i HP 500 - 999 $195.00
ALM12V35i HP 1000 - 5000 $245.00

Email when stock available

SKU: ALM000006-01 Category:

Description

This product is currently out of stock due to high demand. Expected to be available in the May/June timeframe.

ALM 12V35i HP (intelligent w/SM bus, High Power)

HIGH PERFORMANCE, LONG LASTING, SAFE BATTERIES FOR TOUGH, CRITICAL APPLICATIONS

NEC Energy Solutions ALM™ family of lithium-ion batteries offers exceptional performance and long operating life.

The ALM 12V35 delivers significant advantages over lead-acid batteries:

  • High energy capacity even under high discharge rate and deep cycling
  • Industry-leading service life in both cycling and float applications
  • Integrated, redundant safety protection circuits
ALM 12V35 vs. Typical Lead-Acid Equivalent
Available Energy (at 1hr rate) Up to 60% greater
Cycle Life (to 50% DOD) 10–50X longer
Calendar/Float Life Up to 5X longer
Charging Time 10–100X faster
Weight (kg) 50% lighter

Long Life

  • Exceptional 100% deep discharge cycle life
  • Superior float, calendar, and shelf life
  • Excellent partial state-of-charge endurance

#

High Performance

  • High rate power delivery with consistent energy capacity
  • Fast, simple charging. Compatible with most lead acid chargers
  • Integrated intelligence and communications (ALM i-Series)
  • Scalable arrays up to 48V, 350Ah (4S10P) without external Battery Monitoring System (BMS)

Robust Safety

  • EverSafe™ battery technology. Protection at the cell, battery, and system level
  • Fast response short circuit protection
  • Safe, proven, high-performance high-performance Nanophosphate® LiFePO4 chemistry
  • Sealed ABS plastic case (UL 94-5VA flame retardant)
  • Environmentally friendly; cells contain no lead or cadmium

Tough, Critical Applications

  • Strong performance and life across temperature extremes
  • Light weight with superior energy density
  • Simple, scalable system configurability up to 18kWh of energy

ALM 12V35 Applications


# UPS SYSTEMS

  • Data Center, Server, Desktop UPS
  • High discharge and recharge rates allow energy right-sizing and flexibility

# MEDICAL

  • Computer Carts, Beds, Equipment
  • Long cycle life reduces maintenance, even lasting for life of equipment
  • Fast recharge improves usability

# TELECOM BACKUP POWER

  • Base stations, broadband nodes
  • Long cycle and float life supports stable or unstable grid applications
  • Low weight eases pole-top utilization

# ELECTRIC MOBILITY

  • Wheelchairs, Scooters, E-bikes, Toys
  • Long cycle life, deep cycling, fast recharge, and light weight dramatically improve user experience

# SECURITY SYSTEMS

  • Panel Backup, Cameras, Lights
  • Long float life reduces replacements
  • High discharge rate enables right-sizing
#
The ALM12V35 is available in standard (s), intelligent (i), and High Power (HP) series to match application requirements. The i-Series offer integrated CAN or SMbus communications for access to critical battery status, usage tracking, State of Charge (SOC), run time to empty, and other parameters.

Electrical Characteristics @ 25°C
Nominal Voltage 13.2 V
Nominal Capacity (1C)
1
35 Ah
Available Energy
(BOL)
462 Wh
Max. Charge/Discharge Current Pulse (1 sec) 250 A
Max. Inrush Current (Charge or Discharge) 500 A
Max. Continuous Discharge Current (to 100% Depth of Discharge) 210 A
4
Max. Continuous Charge Current 210 A
4
Max. Recommended Charge Voltage 14.4 V
Max. Charge Voltage
(w/o damage)
60 V
Recommended Float Voltage 13.6-14.4V
Recharge time @ max rate 10 minutes @ 6C
Min. Float Voltage 13.6 V
Under-voltage Limit (min) 8 V
Operating Temperature -40 to +60°C
Recommended Storage Temperature
2
-40 to +35°C
Transportation
3
-40 to +80°C

  1. Minimum Capacity – 33.6 Ah at beginning of life (BOL)
  2. Storage at higher temperature reduces the battery’s life
  3. Transportation up to two weeks
  4. Duration of maximum constant current is thermally limited by internal electronics and depends on ambient temperature.

SAFETY AND COMPLIANCE
IEC62133; UL 1973
REACH, RoHS and Battery Directive (2006/66/EC)
Meets FCC 47CFR 15 Class B, IEC61000-6-1,-2, -3, -4, ICES-003
UN Manual of Tests and Criteria Part III 38.3


Typical Discharge Behavior Graphs

#

#

#


Constant Power Discharge End Voltage 30 min 45 min 60 min 90 min 120 min 180 min 240 min
Characteristics in Watts @ 25°C 10V 866 598 456 305 231 156 118
Constant Current Discharge End Voltage 20 min 30 min 45 min 60 min 90 min 120 min 240 min
Characteristics in Amps @ 25°C 10V 105 69 46 35 23 18 9

Downloads

Additional information

Weight 16 lbs
Dimensions 12 × 12 × 10 in